Control in Split Version, which is universally applicable for Recirculating and Contact Refrigerations. With graphic display.
Description
The TMP 2630 built-in control is a split-design control unit that can be used universally for forced-air cooling and contact cooling.
The control panel is equipped with a large graphic display (3.2″) and includes a wide range of functions: - Meaningful user information in plain text (German / English / French) - Temperatures can be logged to a USB stick and read out with Excel or similar - Timer for switching the device, lighting, defrosting, etc. on/off - Configurable keypad lock - Temperature curv...
A room temperature sensor and a defrost limit sensor can be connected.
Note: In the case of forced-air cooling, the temperature sensors are generally already fully installed at the factory.
Outputs: - Fan voltage 12 V DC, max. 2 A (2-stage for “Bäcker-Snack” etc.) - Refrigeration unit (230 V, max. 1200 VA) - Light 1 (230 V, max. 6.3 A, with EVG max. 100 VA) - Light 2 (230 V, max. 6.3 A, with EVG max. 100 VA) - Blade wiper (230 V, 2 A)